Self-reclosing MCCB with Leakage-protection
MTM5-EL
MTM5-EL is an integrated system of smart meters, breakers, and communications. This earth leakage circuit breaker device can realize real-time analysis and display of electrical faults and trip: earth leakage, overload, overvoltage, undervoltage, phase loss, and device locking. These electrical faults and trip information may be recorded on both the device and platform.

The system can realize a pre-alarm before loading failure and full protection. It provides online power management that can prepaid metering function with AMR, billing system and online payment. It realizes real-time power efficiency monitoring and real-time monitoring of electrical circuit breaker parameters (voltage, current, residual current, etc.) that can help identify energy savings and further reduce energy costs through the analysis of collected data. It also has bidirectional communications, remote control, and remote lock. For data protection, it can provide tamper event detection, recording, and reporting. For earth leakage circuit breaker protection can offer power-event alarms.
Technical Specification |
||||
Item Code | MTS3-EL125 | MTS3-EL250 | MTS3-EL400 | MTS3-EL630 |
Standards | IEC60947-2, IEC61009 | |||
Approvals | CCC, CE | |||
Poles | 3P+N | |||
Frame Current (A) | 125 | 250 | 400 | 630 |
Rated Current (A) | 40,50,63,80,100,125 | 100,125,140, 160,180,200, 225,250 |
200,225,250,315, 350,400 |
400,500,630 |
Rated Voltage (Vac) | 400 | |||
Insulation Voltage (Vac) | 800 | |||
Frequency (Hz) | 50/60 | |||
Rated Impulsed Withstand Voltage Uimp (Vac) | 8000 | |||
Acing Distance (mm) | >50 | >100 | ||
Rated Ultimate Short-circuit Breaking Capacity, Icu (kA) | 50 | 65 | ||
Rated Operating Short-circuit Breaking Capacity, Ics (kA) | 35 | 42 | ||
Rated Residual Making and Breaking Capacity (I∆m) (kA) | 12.5 | 20 | ||
Type (Wave Form of the Earth Leakage Sensed) | AC | |||
Rated Residual Current (I∆n) (mA) | 50, 100, 200, 400, 600, 800, AUTO, OFF | 100, 200, 300, 500, 800, 1000, AUTO, OFF | ||
Breaking Time Under I∆n for Delay Type (s) | 0.06/0.1/0.2 for option, 2 I∆n | |||
Breaking Time (s) | I∆n<=0.5, 2 I∆n<=0.2; 52 I∆n<=0.15 | |||
Auto-recloser Time (s) | 20-60 | |||
Over Voltage Protection Value (Vac) | 250-300(+/-5%) | |||
Under Voltage Protection Value (Vac) | 150-200(+/-5%) | |||
Remote Control Delay Time (ms) | <=40ms | |||
Communication Delay Time (ms) | <=200ms | |||
Protections | Overload, Short-Circuit, Earth Leakage, Auto-reclose, Phase Loss, Over voltage and Under voltage | |||
Monitoring of Electrical Circuit Parameter | Current, Voltage, Power, Temperature, Frequecy, Power factor | |||
Parameter Value Setting | Rated residual current value, Long-delay time for overload, Short-delay time for Short circuit, Instantaneous time for Short Circuit, Over votlage protection value, and Under voltage protecdtion value. | |||
Electric Life (times) | 1500 | 1000 | 1000 | 1000 |
Mechanical Life (times) | 8500 | 7000 | 4000 | 4000 |
Connectivity | RS485, infrared and Added-on communication of WIFI, TCP, GPS, NB-IoT, LoRa, Zigbee | RS485, infared, WIFI, TCP integrated inside. Added-on communication of WIFI, TCP, GPS, NB-IoT, LoRa, Zigbee | RS485, infrared and Added-on communication of WIFI, TCP, GPS, NB-IoT, LoRa, Zigbee | |
Software | App and software platform for option | |||
Communication Protocal | TCP, Modbus | |||
Pollution Degree | 2 | |||
Ambient Temperature (°C) | -55 - +40 | |||
Storage Temperature (°C) | -25 - +70 | |||
Humidity | <50% | |||
Altitude (m) | <=2000 | |||
Connection | From top to bottom |
-